Medical Equipment Ireland

 

Arterial Hardness and Blood Pressure Monitor Item 32774 Price € 159.95
The first unit in the world measuring artery stiffening. Arterial hardness measurement complements blood pressure management. Both are needed to ensure a long and healthy life. Measuring arterial hardness and blood pressure on a regular basis will help you to gain knowledge of your cardiovascular condition and provide early diagnosis for treatment. Size: 175 x 90 x 105 mm with cuff storage compartment 30 sets of memories with date/time stamp for blood pressure and pulse rate monitor.

 

24 Hour Blood Pressure Monitor System Item 32780 Price € 209.95

A simple, economic and small size unit for 24 hours ambulatory blood pressure monitoring.
Main features:
- 4 - memory zones, 99 - readings each (total 396 measurements)
- Patient-friendly performance at affordable price
- Automatic measurement by two predetermined intervals
- Irregular Heartbeat detector, detect a disturbance in the regular rhythm of the heartbeat
- Big LCD display showing measuring date and time
- 5 - mode average function, by hour, day, week, month and overall
- Transfer to PC via software and USB plug of measured values
- Lithium battery, long - time measurement.
Supplied with arm cuff (22-24 cm) and software.

 

Technical Specifications

• Measuring type: Oscillometric system • Measuring range: Pressure: 20 ~ 80 mmHg • Pulse: 40~195 beats / min. • Accuracy: - Pressure: ± 3 mmHg - Pulse: ± 5% • Power supply: Lithium Battery, 3.7V 1050mA • Weight: Approx. 260g (including cuff, ex. batteries) • External dimension: 184 x 84 x 33 mm • Arm cuff: 22-34 cm

 

 

ABPM + Pulse rate + SpO2 with software
Item 35111 Price € 795.00

GIMA ABPM module measures the blood pressure using the oscillometric method. There are two modes of measurement available: manual and automatic. Each mode displays the diastolic, systolic and mean blood pressure. In the MANUAL mode, only one measurement is conducted for each time. In the AUTO mode, the measurement is cycled; you can set the interval time to 5/10/15/20/30/45/60/90 minutes - Compact and portable, easy to use - Suitable for adult, pediatric and neonatal patient - Large color LCD display of ABPM, SpO2 and pulse rate - Adjustable audible and visual alarms - Real-time ambulatory monitoring 24 hours storage and review of date - Oscillometry with step deflation - Clinically proven accuracy - All date can be transferred to a PC through Windows-based software for review and print (English)

 

Technical Specifications

• Display: color LCD • Power: two "AA", 1.5V alkaline batteries • Dimension: 120 x 80 x 32 mm • Weight: <350 g (including batteries) • SpO2 (35111 only) - Measurement range: 0-100% - Resolution: 1% - Accuracy: 70-100% ±2% - Alarm range: 0-100% • NIBP - Method: oscillometry - Mode: manual/automatic/continuous - Measurement range: 25-260 mmHg (max 280 mmHg) • Automatic measurement interval: - 5, 10, 15, 30, 45, 60, 90, 120 minutes - Resolution: ImmHg - Overpressure protection: 300 mmHg - Alarm: systolic, diastolic - Mean alarm range: 10-270 mmHg • Pulse rate - Range: 0-254 bpm - Resolution: 1 bpm - Accuracy: ±1 bpm - Alarm range: 0-254 bpm • Operating system: Windows XP, 7

 

 

Up to 52 Hours Ambulatory Blood Pressure Monitor Item 33351 Price € 2795.00

 

 

 

 

 

 

 

The AM100 is a compact, lightweight instrument that provides a cost-effective solution for monitoring patient's blood pressure outside the clinical environment. AM100 employs the popular oscillometric technique of blood pressure measurement that is used in patient monitoring in hospital worldwide. The simplicity of this technique provides for the quickest patient hook-up. AM100 interfaces with Win Pro PC Software for monitor programming as well as report editing and generation.

- Oscillometric technology:
quick hook-up, making it easy to use, saving your staff time

- Compact and quiet:
silent operation and compact size aid patient compliance.

- Low power consumption:
requires only two "AA" batteries, making this unit much less expensive than others.

 

Technical Specifications

• Tecnique: Oscillometry with step deflation
• Accuracy: +/- 3 mmHg
• Display: liquid crystal
• Recording duration: Up to 52 hours
• Sample quantity: Over 250 sample of systolic, diastolic, MAP and heart rate
• Sampling periods: 3 time periods
• Power source: 3 VDC/Two 1.5 V “AA” Alkaline

 

Standard accessories

• Software
• Standard cuff
• Carrying-bag
• PC connection cable
• English manual

 

 

   
 
   
   
   

 

 

 

 